Oct 15, 2016 Update Notes


SOFTWARE CHANGES INCLUDED IN THIS UPDATE:

15 Oct 16 software changes 132 x 42


PHARMACY SYSTEM

1.  BOARD AND CARE (MAR) PRINTOUTS - PRINT DISPENSED DATE + DAYS SUPPLY
Setting the 'Print Most Recent Dispensed Drug' option to 'D' has the effect of
limiting the scripts printed to include scripts whose most recent dispensing
date + days supply is AFTER the 'Print Dispensings After' date.

2.  PICKUP SCRIPT CAN NOW USE P.O.S. INGENICO ISC250 DEVICE
A workstation may now be configured to use an Ingenico iSC250 device for
script pickup signatures.  The 'Signature Pad Settings' configuration in
Terminal Map Maintenance (key strokes from main menu: 3 1 N 5 1 <Enter>)is as
follows:
    1) Sig Pad Socket # - set to the last 3 characters of the P.O.S.
workstation terminal name.  For example, if the terminal name is 'pos1' (or
s3pos1) the Socket# would be 'os1'.
    2) Sig Pad Minimum X AND Y Values must be a positive number.
    3) Sig Pad Type must be set to 'iSC250' (case sensitive. 'ISC250' does NOT
work).
    4) SOFTWARE OPTIONS - MISCELLANEOUS FUNCTIONS - 'P.O.S. Directory' must be
set to the associated P.O.S. directory.  Typically, this is '/home/pos'. (Key
strokes from main menu: 3 1 N 1 <F7>).
- All the other Sig Pad configuration items are ignored.
- This configuration is dependent on the associated P.O.S. workstation being
able to capture signatures on its configured iSC250 device.

3.  ZEBRA (THERMAL) PRE-PACK LABELS - NUMBER OF COPIES
The 'Copies' field is now functioning for thermal labels. Previously, only one
label would print regardless of the number entered in the 'Copies' field.

4.  LOG OF SCRIPTS - REPORT BUILDER - NEW ITEMS
Patient Items have been added:
   42. Pat Cell Carrier
   43. Pat Pref Contact
   44. OBC/OBM WillCall
   45. OBC/OBM Compliance
   46. OBC/OBM Birthday
   47. OBC/OBM Script Proc
   48. OBC/OBM Marketing

5.  CAMERA IMAGING
Configuration for Camera Imaging has been added to Terminal Map Maintenance
AND RX/Document Scanning.  Call FSI SUPPORT for assistance.

6.  SHIPPING 
The shipping program can now interface to Out Bound Messaging.

'OLD' (80x24) SOFTWARE CHANGES

15 Oct 16 Software Notes

PHARMACY SYSTEM

1.  BOARD AND CARE (MAR) PRINTOUTS - PRINT DISPENSED DATE + DAYS SUPPLY
Setting the 'Print Most Recent Dispensed Drug' option to 'D' has the effect of
limiting the scripts printed to include scripts whose most recent dispensing
date + days supply is AFTER the 'Print Dispensings After' date.

2.  PICKUP SCRIPT CAN NOW USE P.O.S. INGENICO ISC250 DEVICE
A workstation may now be configured to use an Ingenico iSC250 device for
script pickup signatures.  The 'Signature Pad Settings' configuration in
Terminal Map Maintenance (key strokes from main menu: 3 1 N 5 1 <Enter>)is as
follows:
    1) Sig Pad Socket # - set to the last 3 characters of the P.O.S.
workstation terminal name.  For example, if the terminal name is 'pos1' (or
s3pos1) the Socket# would be 'os1'.
    2) Sig Pad Minimum X AND Y Values must be a positive number.
    3) Sig Pad Type must be set to 'iSC250' (case sensitive. 'ISC250' does NOT
work).
    4) SOFTWARE OPTIONS - MISCELLANEOUS FUNCTIONS - 'P.O.S. Directory' must be
set to the associated P.O.S. directory.  Typically, this is '/home/pos'. (Key
strokes from main menu: 3 1 N 1 <F7>). THIS CONFIGURATION ITEM MUST BE SETUP
USING THE '132x42' SCREEN SIZE PROGRAM.

- All the other Sig Pad configuration items are ignored.
- This configuration is dependent on the associated P.O.S. workstation being
able to capture signatures on its configured iSC250 device.

3.  CAMERA IMAGING
Configuration for Camera Imaging has been added to Terminal Map Maintenance. 
Call FSI SUPPORT for assistance.


P.O.S. SYSTEM 

- No program changes.

Thank you, and have a nice day.